CAN Code for Initialization

Here’s some code to get going. The ECAN section of the 18F4580 datasheet describes the modules function and how to use it, so I’ll only briefly describe what’s going on.

To write to certain ECAN configuration registers, you must request to enter a Config mode, then wait for the module to enter it. The Baud rate settings are tricky, but can be found easily from here, Request form for CANopen Bit Timings. Only one Receive Filter is used and linked to Receive Buffer 0. To add more Enable the filter in RFCONx, associate to a Receive buffer with RXFBCONx, then set its identifier. Last is to exit the Config mode by requesting either Normal mode or Loopback mode for testing. An important point here is that the ECAN module won’t exit config mode unless the microcontroller is correctly connected to a CAN driver IC, even for going to Loopback mode.

void ECAN_Init(void)
{
    LATB = 0x00;
    TRISBbits.TRISB3 = 1;

    CANCON = 0x80;    //request CONFIG mode
    while(CANSTATbits.OPMODE2==0);

    ECANCON = 0x40;    //Sets ECAN to Mode 1

    BRGCON1 = 0x09;   //Sets Baud rate
    BRGCON2 = 0x84;
    BRGCON3 = 0x00;

    BSEL0 = 0xfc;

    RXM0EIDH = 0x00;    // 0's for EID and SID
    RXM0EIDL = 0x00;
    RXM0SIDH = 0xFF;    // Standard ID FILTER
    RXM0SIDL = 0xE0;    //Mask0 = 0x7ff

    RXFCON0 = 0x01;        //filter 0 enabled
    RXFCON1 = 0x00;        //all others disabled

    MSEL0 = 0xfc;        //Mask0 assigned to Filter0
    MSEL1 = 0xFF;        //all others no mask
    MSEL2 = 0xFF;
    MSEL3 = 0xFF;

    RXFBCON0 = 0x00;    //filter 0 assoc w/ RXB0, 1 w/ RXB1

    RXB0CONbits.RXM1 = 1;

    RXF0SIDH = 0x04;    //Recv Filter0 = 0x020
    RXF0SIDL = 0x00;    //Std. Identifier
    RXF0EIDH = 0x00;
    RXF0EIDL = 0x00;

    CANCON = 0x00;        //Set ECAN to normal mode
    //CANCON = 0x40;        //Set ECAN to Loopback mode(TEST)
    while(CANSTATbits.OPMODE2 == 1);    //wait till out of Config Mode
}//end of ECAN_Init()

When setting up a test bus, start with one node set in Loopback mode. In this mode, the acknowledge bits are ignored and allows the node to receive CAN messages transmitted from itself.This will confirm the baud and filter settings are correct. I made a loop of sending and receiving with counters, then displaying on an LCD(nokia 6100). Once I had my two breadboards able to send and receive the same number of messages, I connected them together. Of course the micrcontroller must be connected to a CAN driver IC, the MCP2551, with a 60Ω resistor connected between the CANH and CANL pins, or the module would never get out of config mode.

The datasheet describes how to transmit a message, and doesn’t need any extra configuration. To receive a message, the ECAN module will accept and place data in the proper register, then set a flag that can be polled. An interrupt can be used too.

Hopefully this helps get others going. Later.

About these ads
  1. Vicent
    April 30, 2012 at 1:02 pm | #1

    Very interesting but can you explain how do you connect 2 nodes by ECAN?

    like your sparta module from control module to connect a button to a relay .
    Defining the ID of each module
    For example:

    BUTTON >> PIC1 >> CANopen >> PIC2 >> output (RELAY of your bells)

    Thanks for your time.
    My email: vafado@hotmail.com

  1. No trackbacks yet.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

Follow

Get every new post delivered to your Inbox.

%d bloggers like this: